{"created":"2023-05-15T08:55:53.033489+00:00","id":672,"links":{},"metadata":{"_buckets":{"deposit":"e4332281-ca1d-46a5-aa0e-d9951fe6fb84"},"_deposit":{"created_by":4,"id":"672","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"672"},"status":"published"},"_oai":{"id":"oai:niit.repo.nii.ac.jp:00000672","sets":["34"]},"author_link":["3546","3547","3544","3545"],"item_6_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-07","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"80","bibliographicPageStart":"77","bibliographicVolumeNumber":"51","bibliographic_titles":[{"bibliographic_title":"日本建築学会北陸支部研究報告集"}]}]},"item_6_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"本研究では,接着系あと施工アンカーにせん断力を作用させたときの諸性能(せん断耐力,変形性状および破壊性状)を実験的に把握することを目的としている。ここでは,へりあき寸法の小さい状況下で接着系アンカーを定着させた場合の,耐力,変形性状および破壊性状を実験により把握し,へりあき寸法,アンカー筋の埋め込み長さが接着系あと施工アンカーの抵抗機構に及ぼす影響およびせん断耐力評価方法について検討した。","subitem_description_type":"Abstract"}]},"item_6_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本建築学会"}]},"item_6_relation_41":{"attribute_name":"関係URI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"http://ci.nii.ac.jp/naid/110006889066"}]}]},"item_6_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"社団法人日本建築学会"},{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_6_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-9622","subitem_source_identifier_type":"ISSN"}]},"item_6_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00188761","subitem_source_identifier_type":"NCID"}]},"item_6_version_type_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"安藤, 祐太郎"}],"nameIdentifiers":[{"nameIdentifier":"3544","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中野, 克彦"}],"nameIdentifiers":[{"nameIdentifier":"3545","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-02-25"}],"displaytype":"detail","filename":"110006889066.pdf","filesize":[{"value":"628.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"110006889066.pdf","url":"https://niit.repo.nii.ac.jp/record/672/files/110006889066.pdf"},"version_id":"806d1889-c07f-48fe-9989-7912e59e3ede"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Post-installed bonded anchor","subitem_subject_scheme":"Other"},{"subitem_subject":"edge distance","subitem_subject_scheme":"Other"},{"subitem_subject":"embedment length","subitem_subject_scheme":"Other"},{"subitem_subject":"shear load acting parallel to the edge","subitem_subject_scheme":"Other"},{"subitem_subject":"shear capacity","subitem_subject_scheme":"Other"},{"subitem_subject":"へりあき寸法","subitem_subject_scheme":"Other"},{"subitem_subject":"接着系あと施工アンカー","subitem_subject_scheme":"Other"},{"subitem_subject":"埋め込み長さ","subitem_subject_scheme":"Other"},{"subitem_subject":"へりあきに平行なせん断力","subitem_subject_scheme":"Other"},{"subitem_subject":"せん断耐力","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"接着系あと施工アンカーのせん断耐力に及ぼすへりあき効果の影響","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"接着系あと施工アンカーのせん断耐力に及ぼすへりあき効果の影響","subitem_title_language":"ja"},{"subitem_title":"Influence of Edge distance for Shear capacity of Post-installed bonded anchor","subitem_title_language":"en"}]},"item_type_id":"6","owner":"4","path":["34"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2011-08-03"},"publish_date":"2011-08-03","publish_status":"0","recid":"672","relation_version_is_last":true,"title":["接着系あと施工アンカーのせん断耐力に及ぼすへりあき効果の影響"],"weko_creator_id":"4","weko_shared_id":-1},"updated":"2023-06-21T09:11:04.908526+00:00"}