{"created":"2023-05-15T08:55:29.299469+00:00","id":220,"links":{},"metadata":{"_buckets":{"deposit":"d343f37b-8a3e-451e-aa12-cb4c71c99818"},"_deposit":{"created_by":4,"id":"220","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"220"},"status":"published"},"_oai":{"id":"oai:niit.repo.nii.ac.jp:00000220","sets":["6:7:25"]},"author_link":["905","906","907","902","903","904"],"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013-12","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"8","bibliographicPageStart":"1","bibliographicVolumeNumber":"18","bibliographic_titles":[{"bibliographic_title":"新潟工科大学研究紀要"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In this study, we constructed a simulation model to generate a surface EMG during isometric exercise. The surface EMG was detected using both unipolar and bipolar lead systems, and the measurement performance of both systems was compared. When detecting surface EMGs using the unipolar lead system, low-frequency components were increased to a greater extent than in the bipolar lead system, suggesting that the unipolar lead system is more suitable for the detection of surface EMGs","subitem_description_type":"Abstract"}]},"item_2_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"新潟工科大学"}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1342-792X","subitem_source_identifier_type":"ISSN"}]},"item_2_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10590360","subitem_source_identifier_type":"NCID"}]},"item_2_version_type_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"堀田, 優"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"小浦方, 裕騎"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"伊藤, 建一"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-02-25"}],"displaytype":"detail","filename":"18_1-8.pdf","filesize":[{"value":"839.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"18_1-8.pdf","url":"https://niit.repo.nii.ac.jp/record/220/files/18_1-8.pdf"},"version_id":"f6231d98-6e31-471c-a3f1-a7b70bfeb51c"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Surface EMG"},{"subitem_subject":"Bipolar lead system"},{"subitem_subject":"Unipolar lead system"},{"subitem_subject":"Muscle fatigue"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"表面筋電図生成モデルを用いた双極・単極誘導法の筋疲労検出力の検証","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"表面筋電図生成モデルを用いた双極・単極誘導法の筋疲労検出力の検証","subitem_title_language":"ja"},{"subitem_title":"Verification of muscle fatigue detection capability of unipolar and bipolar lead systems using surface EMG generation model","subitem_title_language":"en"}]},"item_type_id":"2","owner":"4","path":["25"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-01-22"},"publish_date":"2014-01-22","publish_status":"0","recid":"220","relation_version_is_last":true,"title":["表面筋電図生成モデルを用いた双極・単極誘導法の筋疲労検出力の検証"],"weko_creator_id":"4","weko_shared_id":-1},"updated":"2023-06-20T05:58:10.908036+00:00"}