@article{oai:niit.repo.nii.ac.jp:00000188, author = {飯野, 秋成}, journal = {新潟工科大学研究紀要}, month = {Dec}, note = {Energy consumption of commercial buildings, hotels and medical facilities in Niigata prefecture was analyzed based on questionnaire survey. Base unit requirements were obtained as follows; 3.36 GJ/m2・year in commercial facilities, 2.50 GJ/m2・year in hotels, and 3.46 GJ/m2 ・year in medical facilities. It was clarified by the multiple regression analysis that the base unit amount of energy consumptions were related on four explanatory variables; business hours in a year, air-conditioning period of year, heating period of year and contracted amount of electric power. And also the existence of an atrium largely influenced on the amount of base unit of energy consumptions at GMS.}, pages = {55--58}, title = {新潟県内の商業・宿泊・医療施設における年間エネルギー消費量の実態調査}, volume = {14}, year = {2009} }