WEKO3
アイテム
{"_buckets": {"deposit": "bdaca9b6-ae30-41a8-8f0a-bc07b0da06ef"}, "_deposit": {"created_by": 4, "id": "54", "owners": [4], "pid": {"revision_id": 0, "type": "depid", "value": "54"}, "status": "published"}, "_oai": {"id": "oai:niit.repo.nii.ac.jp:00000054", "sets": ["11"]}, "author_link": ["198", "199", "196", "197"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1999-12", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "48", "bibliographicPageStart": "43", "bibliographicVolumeNumber": "4", "bibliographic_titles": [{"bibliographic_title": "新潟工科大学研究紀要"}]}]}, "item_2_description_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_2_description_39": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "論文(Article)", "subitem_description_type": "Other"}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In this paper, a method for evaluating the regional wind environment is discussed with the result of the wind tunnel tests and AMeDASA data. The distributions of velocity field in two cases of different building patterns are measured and analyzed in detail. It becomes clear that influences of building shape pattern, building coverage ratios and meteorological conditions on the wind environment is very large.", "subitem_description_type": "Abstract"}]}, "item_2_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "198", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Tominaga, Yoshihide"}]}, {"nameIdentifiers": [{"nameIdentifier": "199", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Hasegawa, Masaki"}]}]}, "item_2_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "新潟工科大学"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1342-792X", "subitem_source_identifier_type": "ISSN"}]}, "item_2_source_id_9": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10590360", "subitem_source_identifier_type": "NCID"}]}, "item_2_text_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_text_value": "http://hdl.handle.net/10623/25409"}]}, "item_2_version_type_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "富永, 禎秀"}], "nameIdentifiers": [{"nameIdentifier": "196", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "長谷川, 正樹"}], "nameIdentifiers": [{"nameIdentifier": "197", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-02-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "niit_78_4_43-48.pdf", "filesize": [{"value": "785.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 785000.0, "url": {"label": "niit_78_4_43-48.pdf", "url": "https://niit.repo.nii.ac.jp/record/54/files/niit_78_4_43-48.pdf"}, "version_id": "3db04437-7f65-4a7e-9e41-ed424eaacbf2"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Building pattern", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Wind Environment", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Wind Tunnel Tests", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "風洞実験に基づく市街地形状の違いによる風環境変化に関する研究", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "風洞実験に基づく市街地形状の違いによる風環境変化に関する研究", "subitem_title_language": "ja"}, {"subitem_title": "Study on Effect of Building Pattern on Wind Environment by means of Wind Tunnel Tests", "subitem_title_language": "en"}]}, "item_type_id": "2", "owner": "4", "path": ["11"], "permalink_uri": "https://niit.repo.nii.ac.jp/records/54", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-02-28"}, "publish_date": "2011-02-28", "publish_status": "0", "recid": "54", "relation": {}, "relation_version_is_last": true, "title": ["風洞実験に基づく市街地形状の違いによる風環境変化に関する研究"], "weko_shared_id": -1}
風洞実験に基づく市街地形状の違いによる風環境変化に関する研究
https://niit.repo.nii.ac.jp/records/54
https://niit.repo.nii.ac.jp/records/54445b9195-09a1-4139-99e0-01f0c750112c
名前 / ファイル | ライセンス | アクション |
---|---|---|
niit_78_4_43-48.pdf (785.0 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-02-28 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 風洞実験に基づく市街地形状の違いによる風環境変化に関する研究 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Study on Effect of Building Pattern on Wind Environment by means of Wind Tunnel Tests | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題 | Building pattern | |||||
キーワード | ||||||
主題 | Wind Environment | |||||
キーワード | ||||||
主題 | Wind Tunnel Tests | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
富永, 禎秀
× 富永, 禎秀× 長谷川, 正樹 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In this paper, a method for evaluating the regional wind environment is discussed with the result of the wind tunnel tests and AMeDASA data. The distributions of velocity field in two cases of different building patterns are measured and analyzed in detail. It becomes clear that influences of building shape pattern, building coverage ratios and meteorological conditions on the wind environment is very large. | |||||
書誌情報 |
新潟工科大学研究紀要 巻 4, p. 43-48, 発行日 1999-12 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1342-792X | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10590360 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | 新潟工科大学 |