WEKO3
アイテム
{"_buckets": {"deposit": "3cdaefe5-43d4-4736-bf27-1904e8d14c95"}, "_deposit": {"created_by": 4, "id": "35", "owners": [4], "pid": {"revision_id": 0, "type": "depid", "value": "35"}, "status": "published"}, "_oai": {"id": "oai:niit.repo.nii.ac.jp:00000035", "sets": ["10"]}, "author_link": ["114", "115", "112", "113"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1998-12", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "40", "bibliographicPageStart": "33", "bibliographicVolumeNumber": "3", "bibliographic_titles": [{"bibliographic_title": "新潟工科大学研究紀要"}]}]}, "item_2_description_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_2_description_39": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "論文(Article)", "subitem_description_type": "Other"}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Restoration of motor functions of paralyzed patients by means of Functional Electrical Stimulation (FES) is effective as a medical treatment. In the clinical application of FES, the traditional evaluation of the electrode failure is difficult and often requires surgical operation, because the electrodes have been percutaneously implanted into the neuromuscular system of the patients. Hence an evakuting method of the condition of the electrodes with non-invasive procedure should be developed, and a useful method with measuring electrical impedance of the electrodes has been reported. Although model circuits in that method can describe the property of the patients\u0027 electrodes, parameters (registers and capacitors) in the models have not been discussed quantitatively. Therefore we evaluate the parameters in this paper. We calculate them from impedance data measured from the patients\u0027 electrodes (In vivo), and compare them to those measured from in vitro experiments. The result verifies that the parameters, i.e. the models in that method, can characterize the electrode condition.", "subitem_description_type": "Abstract"}]}, "item_2_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "114", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Murakami, Hajime"}]}, {"nameIdentifiers": [{"nameIdentifier": "115", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Nunomura, Shigetomo"}]}]}, "item_2_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "新潟工科大学"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1342-792X", "subitem_source_identifier_type": "ISSN"}]}, "item_2_source_id_9": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10590360", "subitem_source_identifier_type": "NCID"}]}, "item_2_text_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_text_value": "http://hdl.handle.net/10623/25386"}]}, "item_2_version_type_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "村上, 肇"}], "nameIdentifiers": [{"nameIdentifier": "112", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "布村, 成具"}], "nameIdentifiers": [{"nameIdentifier": "113", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-02-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "niit_72_3_33-40.pdf", "filesize": [{"value": "414.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 414200.0, "url": {"label": "niit_72_3_33-40.pdf", "url": "https://niit.repo.nii.ac.jp/record/35/files/niit_72_3_33-40.pdf"}, "version_id": "ddb367ce-2850-411e-9e57-125e57ba9041"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Functional Electrical Stimulation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Percutaneously implanted electrodes", "subitem_subject_scheme": "Other"}, {"subitem_subject": "electrode failure", "subitem_subject_scheme": "Other"}, {"subitem_subject": "electrical impedance", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "電気インピーダンスによる生体内埋め込み電極の状態評価に関する基礎的検討", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "電気インピーダンスによる生体内埋め込み電極の状態評価に関する基礎的検討", "subitem_title_language": "ja"}, {"subitem_title": "Fundamental study on evaluation of the condition of percutaneously implanted electrodes with measuring electrical impedance", "subitem_title_language": "en"}]}, "item_type_id": "2", "owner": "4", "path": ["10"], "permalink_uri": "https://niit.repo.nii.ac.jp/records/35", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-02-28"}, "publish_date": "2011-02-28", "publish_status": "0", "recid": "35", "relation": {}, "relation_version_is_last": true, "title": ["電気インピーダンスによる生体内埋め込み電極の状態評価に関する基礎的検討"], "weko_shared_id": -1}
電気インピーダンスによる生体内埋め込み電極の状態評価に関する基礎的検討
https://niit.repo.nii.ac.jp/records/35
https://niit.repo.nii.ac.jp/records/351af4f22f-7eb0-4f5a-acc0-ffa83e642918
名前 / ファイル | ライセンス | アクション |
---|---|---|
niit_72_3_33-40.pdf (414.2 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-02-28 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 電気インピーダンスによる生体内埋め込み電極の状態評価に関する基礎的検討 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Fundamental study on evaluation of the condition of percutaneously implanted electrodes with measuring electrical impedance | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題 | Functional Electrical Stimulation | |||||
キーワード | ||||||
主題 | Percutaneously implanted electrodes | |||||
キーワード | ||||||
主題 | electrode failure | |||||
キーワード | ||||||
主題 | electrical impedance | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
村上, 肇
× 村上, 肇× 布村, 成具 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Restoration of motor functions of paralyzed patients by means of Functional Electrical Stimulation (FES) is effective as a medical treatment. In the clinical application of FES, the traditional evaluation of the electrode failure is difficult and often requires surgical operation, because the electrodes have been percutaneously implanted into the neuromuscular system of the patients. Hence an evakuting method of the condition of the electrodes with non-invasive procedure should be developed, and a useful method with measuring electrical impedance of the electrodes has been reported. Although model circuits in that method can describe the property of the patients' electrodes, parameters (registers and capacitors) in the models have not been discussed quantitatively. Therefore we evaluate the parameters in this paper. We calculate them from impedance data measured from the patients' electrodes (In vivo), and compare them to those measured from in vitro experiments. The result verifies that the parameters, i.e. the models in that method, can characterize the electrode condition. | |||||
書誌情報 |
新潟工科大学研究紀要 巻 3, p. 33-40, 発行日 1998-12 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1342-792X | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10590360 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | 新潟工科大学 |