{"_buckets": {"deposit": "b3b3d556-87f6-4868-bf02-06b19141ea6e"}, "_deposit": {"created_by": 4, "id": "19", "owners": [4], "pid": {"revision_id": 0, "type": "depid", "value": "19"}, "status": "published"}, "_oai": {"id": "oai:niit.repo.nii.ac.jp:00000019", "sets": ["9"]}, "author_link": ["50", "51", "52", "53"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1997-12", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "17", "bibliographicPageStart": "9", "bibliographicVolumeNumber": "2", "bibliographic_titles": [{"bibliographic_title": "新潟工科大学研究紀要"}]}]}, "item_2_description_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_2_description_39": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "論文(Article)", "subitem_description_type": "Other"}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Knee motion was measured with an instrumented spatial linkage (accuracy ; linear ± 500μm, angular ± 0.5°) fixed with intracortical Kirschner wires in five healthy male volunteers (five knees, judged clinically to be normal). This technique allows an accurate description of the relative angular and linear movements between tibia and femur without the effect of skin movement relative to the bone, and changing muscle volume. Motion of the tibia relative to the femur was described in terms of three clinically meaningful rotations and three translations between full extension and 60° flexion ; (a) abduction and adduction ; 3.4 ± 1.2° , (b) internal and external rotation ; 10.6 ± 2.8°; representing screw home motion, (c) anterior and posterior ; 5.2 ± 1.7mm ; representing roll back phenomenon, (d) proximal and distal ; 1.2 ± 2.7mm, (e) medial and lateral ; 1.1 ± 2.6mm.", "subitem_description_type": "Abstract"}]}, "item_2_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "新潟工科大学"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1342-792X", "subitem_source_identifier_type": "ISSN"}]}, "item_2_source_id_9": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10590360", "subitem_source_identifier_type": "NCID"}]}, "item_2_text_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_text_value": "http://hdl.handle.net/10623/29509"}]}, "item_2_version_type_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Terashima, Shojiro"}], "nameIdentifiers": [{"nameIdentifier": "50", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishii, Yoshinori"}], "nameIdentifiers": [{"nameIdentifier": "51", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Terajima, Kazuhiro"}], "nameIdentifiers": [{"nameIdentifier": "52", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Koga, Yoshio"}], "nameIdentifiers": [{"nameIdentifier": "53", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-02-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "2011_1_niit1_052.pdf", "filesize": [{"value": "762.7 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 762700.0, "url": {"label": "2011_1_niit1_052.pdf", "url": "https://niit.repo.nii.ac.jp/record/19/files/2011_1_niit1_052.pdf"}, "version_id": "89c5bdca-3ee7-4dd4-a2fe-ceaf38f666a9"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Motion Analysis", "subitem_subject_scheme": "Other"}, {"subitem_subject": "In Vivo", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Knee Kinematics", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Three Dimensional", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "In Vino Three-Dimensional Kinematics of the Human Knee", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "In Vino Three-Dimensional Kinematics of the Human Knee", "subitem_title_language": "en"}]}, "item_type_id": "2", "owner": "4", "path": ["9"], "permalink_uri": "https://niit.repo.nii.ac.jp/records/19", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-11-15"}, "publish_date": "2011-11-15", "publish_status": "0", "recid": "19", "relation": {}, "relation_version_is_last": true, "title": ["In Vino Three-Dimensional Kinematics of the Human Knee"], "weko_shared_id": -1}
In Vino Three-Dimensional Kinematics of the Human Knee
https://niit.repo.nii.ac.jp/records/19
https://niit.repo.nii.ac.jp/records/198612d13f-4a6a-4e20-aa1b-1d82514f78f2
名前 / ファイル | ライセンス | アクション |
---|---|---|
2011_1_niit1_052.pdf (762.7 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-11-15 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | In Vino Three-Dimensional Kinematics of the Human Knee | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題 | Motion Analysis | |||||
キーワード | ||||||
主題 | In Vivo | |||||
キーワード | ||||||
主題 | Knee Kinematics | |||||
キーワード | ||||||
主題 | Three Dimensional | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
Terashima, Shojiro
× Terashima, Shojiro× Ishii, Yoshinori× Terajima, Kazuhiro× Koga, Yoshio |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Knee motion was measured with an instrumented spatial linkage (accuracy ; linear ± 500μm, angular ± 0.5°) fixed with intracortical Kirschner wires in five healthy male volunteers (five knees, judged clinically to be normal). This technique allows an accurate description of the relative angular and linear movements between tibia and femur without the effect of skin movement relative to the bone, and changing muscle volume. Motion of the tibia relative to the femur was described in terms of three clinically meaningful rotations and three translations between full extension and 60° flexion ; (a) abduction and adduction ; 3.4 ± 1.2° , (b) internal and external rotation ; 10.6 ± 2.8°; representing screw home motion, (c) anterior and posterior ; 5.2 ± 1.7mm ; representing roll back phenomenon, (d) proximal and distal ; 1.2 ± 2.7mm, (e) medial and lateral ; 1.1 ± 2.6mm. | |||||
書誌情報 |
新潟工科大学研究紀要 巻 2, p. 9-17, 発行日 1997-12 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1342-792X | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10590360 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | 新潟工科大学 |